Social activities of Guangdong SOXI Intelligent Equipment Co., Ltd. Skill competition Safety production emergency drill Classification, Working Principles and Precautions for Common Vacuum Hopper Loade What Are the Methods to Choose an Industrial Chiller? The Development Trend of Plastic Dryer in the Next Few Years Characteristics of Dehumidifying Dryer (Standard Type) What is a Central Conveying System? The Determinants of Drying Rate of Dehumidifying Dryer Material The Difference between Dehumidifying Dryer and Ordinary Dryer What Are the Structural Functions of the Injection Molding Machine? Introduction to the Principle, Application Range and Characteristics of Hot Air Hopper Dryers December employee birthday party Working Principle and Operation of Plastic Moulding Machine How Can the Mold Temperature Machine Be Cooled? Classification of Plastic Moulding Machines The Principle, Use and Classification of Plastic Crusher How to Choose an Industrial Chiller? Moulding Method of Plastic Moulding Machine What is Central Conveying System? Development Trend of Plastic Dryers in Next Few Years Plastic Molding Methods for Central Conveying System Pipeline Layout Requirements and Maintenance Methods of Central Conveying System Classification, Working Principle and Attention Points of Common Vacuum Hopper Loader The Difference Between Central Feeding System and Automatic Feeding System How to Control the Water Volume of the Three-in-one Dehumidification Dryer? Classification and Selection Skills of Dehumidification Dryers What Should Be Paid Attention to in the Drying Gas Path of the Dehumidifying Dryer? Three-in-one Dehumidifier and Dryer Humidity Measurement Method What is the Function of the Various Accessories of the Dehumidifying Dryer? What is the Difference Between a Plastic Dehumidifying Dryer and a Dehumidifying Dryer (Standard Type)? Complete Solution for Central Conveying System What is the Appropriate Temperature for the Dehumidifying Dryer? What Do I Need to Do Before a New Dehumidifying Dryer Can Be Used? Instructions for Use of the Dehumidifier Dryer (Standard Type) Application Introduction of Industrial Chiller Dynamic Heat Balance of Mold Temperature Machine: Mold Temperature Control is Essential Plastic Shredder Machines Play an Important Role in Waste Plastic Recycling What Details Should Be Paid Attention to when the Central Conveying System Fails? Maintenance of High-pressure Fans for Central Conveying Systems What Are the Factors That Affect the Price of Dehumidifying Dryers? What is the Drying Temperature of the Dehumidifying Dryer? Three Important Steps to Safely Operate Injection Molding Machines Five Criteria for Mold Temperature Machine Selection Why Use a Mold Temperature Machine? Intelligent Central Conveying System to Help You Realize Intelligent Injection Molding Factory The Conveying Principle of the Central Conveying System Automatic Vacuum Hopper Loader is Widely Used in Industrial Development Fault Detection and Troubleshooting Methods for Dehumidifying Dryer Choose Dehumidifying Dryer according to Material. Can Mold Temperature Machine Cool Down? Drying Process of Dehumidification Dryer The Application of Dehumidifying Dryer (Standard Type) Precautions Before Using Dehumidifiying Dryer Precautions of Using Heat Conducting Oil Principle and Precautions of Dehumidifying Dryer The Characteristics of High-pressure Blower with Central Conveying System Composition of the Central Conveying System Method of Using Central Conveying System and the Benefits of It‘s’ Installation Measurement and Precautions of Dehumidification Dryer's Dew Point How to Choose a High-Quality Central Conveying System? Introduction to the Application of Industrial Chiller How to Vent an Industrial Chiller? Treatment and Functions of Dehumidifying Dryer (Standard Type) Actual Steps for Using Industrial Chiller Unit What Types of Dehumidifying Dryer Can Be Classified by Pressure? Dehumidifying Dryer Dehumidification Mode and Working Principle Advantages of Central Conveying System Planned for Injection Molding Workshop Design Process and Characteristics of Central Conveying System How to Quantify the Central Conveying System? What Is the Importance of Central Conveying System Components? What Problems Can the Central Conveying System Solve? What Are the Reasons That Affect the Effectiveness of Dehumidifying Dryer? What Are the Advantages of Central Conveying System Compared to Individual Feeding on the Machine? What Is the Drying Method of Dehumidifying Dryer? The Differences of Industrial Chiller Performance in Various Environments Introduction to the Working Principle of a Dehumidifying Dryer (Standard Type) How to Use the Mold Temperature Machine Correctly?
Search
×

Actual Steps for Using Industrial Chiller Unit


Conventional chillers are integrated structures that produce significant noise during operation, causing noise pollution for users. This makes it difficult to operate for long periods of time. Additionally, conventional chillers are large and cumbersome, occupying a lot of space. For limited spaces, they are inconvenient to use and cost a lot.


Split-type industrial chiller structure


A split-type industrial chiller machine is made up of an outdoor unit and an indoor unit connected by pipes. The outdoor unit consists of a finned condenser and a radiator fan, while the indoor unit consists of a compressor, water pump, evaporator, temperature display control chiller mechanism, and water tank. The outdoor unit emits noise and heat, which reduces noise within the indoor environment without generating too much heat.


Installation requirements for split-type industrial chiller machine


Split-type industrial water chiller must be installed separately and has high requirements for their placement. The outdoor unit must be installed in a well-ventilated location with shade and clean surroundings.


Application environment for split-type industrial chiller machine


Split-type industrial chillers are suitable for experimental and research centers, academic research institutions, etc. The low noise level of the indoor unit during operation makes it ideal for sites with strict production environment requirements.


Steps for using the industrial chiller machine


Firstly, according to the manufacturer's instructions, all routes must be secure before using the industrial water chiller unit. Then, turn on the manual switch and open the exhaust valve of the air compressor at the same time, and observe the position of the valve pointer. If it is within the normal range, the industrial chiller unit can operate normally.


Secondly, turn on the electric heating button. When the environmental temperature reaches above 40 degrees Celsius, turn off the heating button immediately. The entire heating process for the industrial chiller unit is relatively short and only takes a few minutes.


Thirdly, start the water pump's operation button. You will hear the industrial chiller machine unit's water pump gradually supplying electricity, and then it will gradually use the primary functions of the cooling tower to operate successfully.


Since its establishment, SOXI has always adhered to the business principle of putting people first and emphasizing honesty. They have gathered industry elites to combine foreign advanced information technology, management methods, and business experience with domestic practical experience to provide a full range of automation solutions for plastic auxiliary machines. This helps companies improve their management and production capabilities, maintain competitiveness in fierce market competition and achieve rapid and stable development. The company's experience combined with the practical experience of domestic enterprises provides a full range of automation solutions, helping companies improve their management and production capabilities, maintain competitiveness in fierce market competition, and achieve rapid and stable development.


Popular Plastic Molding & Auxiliary Machinery Products